Dimensions / Building materials / Drywall / Regular drywall

Regular Drywall Sizes: Sheets, Thickness, Weight and Framing

Regular drywall is sold 48 in wide (1220 mm) in lengths of 8, 9, 10, 12, 14 and 16 ft, plus 54 in × 12 ft, in 1/2 and 5/8 in board (GA-223). Half-inch board weighs 1.25 lb/ft² in USG’s UltraLight and up to 1.6 lb/ft² in regular-weight board, so a 4 × 8 ft sheet is about 40 to 51 lb. The IRC lets 1/2 in board span framing 24 in apart on walls and across ceiling joists, but only 16 in along them. In Europe the same board is EN 520 Type A: 1200 × 2400 mm at 9.5, 12.5 or 15 mm, about 6.0, 8.0 and 10.0 kg/m² at Siniat.

Sheet (GA-223)Half-inch, USG UltraLightJoists, 1/2 in across (IRC)
4 × 8ft1220 × 2440 mm1.25lb/ft²6.1 kg/m²24in610 mm

Sources: Gypsum Association, USG, IRC. Checked October 2026.

Regular drywall (gypsum wallboard) with its usual width, depth and height marked
Annotated in SizeMarkerOpen this image in the editor →The boards are an illustration; the labels show the nominal 4 × 8 ft sheet, not a measurement of these boards.Free to use with a link back:

Will your drywall add up and pass?

USG’s half-inch UltraLight on a wall and a ceiling is filled in. Enter your wall, sheets, framing and a sheet you measured, or switch to European rules; each check follows a figure or rule on this page.

Regular drywall

Wall and sheets

ft
ft
in
ft
lb/ft²

Framing

in

A sheet you measured

in
in

Sheet counts are whole sheets with no offcuts reused. Enter the weight your maker prints: lightweight and regular half-inch board differ by a quarter.

How many sheets does the wall take?Enough

Hung upright, a 14 ft wall takes 4 sheets 48 in wide, each reaching the 8 ft height; you have 4. Each sheet is 32 ft² and weighs about 40 lb at 1.25 lb/ft², 160 lb for 4; the Gypsum Association asks for two or more people to carry one.

USG UltraLight at 1.25 lb/ft² on a 14 ft wall is filled in; sheets are counted whole, with no offcuts reused.

Will the framing carry this board?Allowed

IRC Table R702.3.5 allows framing up to 24 in apart for 1/2 in board on a ceiling across the framing; yours is 24 in. Nail every 7 in or screw every 12 in along each member.

Half-inch board across ceiling joists 24 in apart is as wide as the IRC lets it go.

Is the board within tolerance?Within

Measured 47-15/16 × 95-7/8 in against 48 × 96 in: inside the ±3/32 in on width and ±1/4 in on length that Georgia-Pacific prints.

Georgia-Pacific prints ±3/32 in on width and ±1/4 in on length; the readings are an example.

Selling wallboard? Photograph a sheet and its edge, mark the size, the thickness, the edge type and the weight in SizeMarker and send it with your quote.

Mark a photo

Nine real regular boards

Maker sheets; sizes and weights as each prints them. The UK boards are EN 520 Type A.

BoardSizesThicknessWeight, as printed
USG Sheetrock UltraLightThis page48 or 54 in × 8–16 ft (1219 or 1372 × 2438–4877 mm)1/2 in (12.7 mm)1.25 lb/ft² (6.1 kg/m²)
USG Sheetrock gypsum panels4 ft × 8–16 ft1/4, 3/8 in1.2 / 1.4 lb/ft²
CertainTeed Easi-Lite4 ft or 54 in × 8–16 ft1/2 in1.2–1.4 lb/ft²
Georgia-Pacific ToughRock Lite-Weight4 ft × 8–16 ft; width ±3/32 in, length ±1/4 in1/2 in1.45 lb/ft²
Gold Bond High Strength LITE4 ft × 8–14 ft; 54 in × 12–14 ft1/2 in1.3–1.4 lb/ft²
PABCO Regular48 in × 8–15 ft; 54 in × 10 or 12 ft1/4, 3/8, 1/2 in1/2 in: 1.5 lb/ft² at 48 in, 1.6 at 54 in
Siniat Standard BoardUK900 or 1200 × 1800–3000 mm9.5, 12.5, 15 mm6.0 / 8.0 / 10.0 kg/m²
British Gypsum Gyproc WallBoardUK, 2015900 or 1200 × 1800–3000 mm; 3600 mm at 12.5 mm9.5, 12.5, 15 mm6.3 / 8.0 / 9.8 kg/m²
Knauf WallboardUK900 or 1200 × 1800–3000 mm9.5, 12.5, 15 mm6.1 / 8.1 / 10.1 kg/m²

Sources: USG · USG · CertainTeed · Georgia-Pacific · National Gypsum · PABCO · Siniat · Siniat · British Gypsum · Knauf

Sizes by thickness

Not every type comes in every size (GA-223); makers print their own ranges.

ThicknessWidthsLengthsTypical use
1/4 in (6.4 mm)48 in8, 9, 10 ftRemodeling, double layers, curved surfaces
3/8 in (9.5 mm)48 in8, 9, 10 ftRemodeling, double-layer walls and ceilings, curves
1/2 in (12.7 mm)48 in; 54 in at 12 ft8, 9, 10, 12, 14, 16 ftAny interior use
5/8 in (15.9 mm)48 in; 54 in at 12 ft8, 9, 10, 12, 14, 16 ftAny interior use
54 in boardGeorgia-Pacific54 in—Two rows hung sideways cover a 9 ft wall with no filler strip
Metric designationsGA-223; USG1220 or 1370 mm2440 to 4880 mmGA-223 rounds; USG prints 1219 × 2438 mm

Sources: Gypsum Association · Georgia-Pacific · USG

Framing: IRC 2021 Table R702.3.5, no adhesive

Largest spacing of the framing in inches on centre; the code sets spacing, not counts.

BoardWallCeiling, across the joistsCeiling, along the joists
3/8 in16 in16 inNot allowed
1/2 in24 in (610 mm)24 in16 in
5/8 in24 in24 in16 in
Water-based ceiling textureNote d—1/2 in up to 16 in; 5/8 in or sag-resistant 1/2 in at 24 inNo single layer of 3/8 in
Nails / screws along each member8 in / 16 in on 16 in framing, 12 in on 24 in7 in / 12 in7 in / 12 in

Sources: IRC

Weight, handling and fixing

ItemFigure
A half-inch sheet, 4 × 8 ftOur calculation40 lb at 1.25 lb/ft²; about 51 lb at 1.6 lb/ft²
Design dead loadGA-235-101/2 in 2.0 psf (9.8 kg/m²), 5/8 in 2.5 psf: values for structural sums, heavier than the sheets
HandlingGA-801-2023Two or more people a panel; a 4 × 12 ft × 1/2 in panel can weigh over 80 lb (36 kg); stacks 17 ft (5 m) high at most
Screw lengthIRC R702.3.5.1; SiniatAt least 5/8 in into wood: 1-1/8 in for 1/2 in board, 1-1/4 in for 5/8 in. Siniat: board plus 25 mm into timber, 10 mm into metal
Ceiling insulationGold Bond; American Gypsum1/2 in regular board carries 1.3 psf at 24 in, 2.2 psf at 16 in; 3/8 in none
Where the IRC asks for 1/2 inIRC R302.6, R302.7, R316.4Garage side of the wall to the house, enclosed space under stairs, thermal barrier over foam plastic
EN 520 tolerancesKnaufWidth +0/−4 mm, length +0/−5 mm, thickness ±0.5 mm; squareness 2.5 mm per metre of width
Siniat framingSiniat Drywall ManualC studs at most 600 mm apart, screws 300 mm apart; ceiling joists 450 mm for 12.5 and 15 mm board, 600 mm with intermediate noggings
In the check aboveOur calculationA 14 ft wall ÷ 48 in = 3.5, so 4 sheets of 4 × 8 ft, 40 lb each and 160 lb in all; 47-15/16 × 95-7/8 in against 48 × 96 in. Europe: 3600 ÷ 1200 mm = 3 boards 2395 mm long against 2400 mm, 23 kg each; 1198 × 2397 × 12.6 mm

Sources: Gypsum Association · Gypsum Association · IRC · IRC · National Gypsum · American Gypsum · Knauf · Siniat · Siniat

Other drywall types

Questions

What size is regular drywall?

48 in (1220 mm) wide and 8, 9, 10, 12, 14 or 16 ft long in 1/2 and 5/8 in board, plus 54 in × 12 ft (GA-223). 1/4 and 3/8 in board comes 8 to 10 ft long in GA-223, though USG prints lengths to 16 ft.

How much does a sheet of 1/2 inch drywall weigh?

About 40 lb for a 4 × 8 ft sheet of lightweight board at 1.25 lb/ft² (USG UltraLight) and about 51 lb at 1.6 lb/ft², the heaviest regular-weight board here. The Gypsum Association’s 2.0 psf is a design dead load, not a sheet weight.

How far apart can studs and joists be for 1/2 inch drywall?

24 in on walls and on ceilings with the long edge across the joists; 16 in where it runs along them (IRC Table R702.3.5). Under a water-based ceiling texture, 1/2 in board is limited to 16 in.

Can 3/8 inch drywall go on a ceiling?

Only across joists up to 16 in apart, and never as a single layer under a water-based texture or carrying insulation (IRC Table R702.3.5 note d).

How long should drywall screws be?

Long enough to go at least 5/8 in into the wood (IRC R702.3.5.1): 1-1/8 in for 1/2 in board and 1-1/4 in for 5/8 in. Siniat asks for the board thickness plus 25 mm into timber.

What is regular plasterboard in Europe?

EN 520 Type A board, 1200 × 2400 mm and also 900 mm wide and up to 3000 mm long, at 9.5, 12.5 or 15 mm. Siniat prints 6.0, 8.0 and 10.0 kg/m²; British Gypsum 6.3, 8.0 and 9.8.

For gypsum board plants exporting wallboard

Buyers ask for the width, length and thickness with their tolerances, the edge, the standard (ASTM C1396 or EN 520 Type A), the weight per square foot or metre, whether it is lightweight or sag-resistant ceiling board, and sheets and weight per pallet. Mark the real sheet and its edge on your own photo in SizeMarker, as in the picture at the top, and send one product card for WhatsApp or WeChat.

Building material spec diagram →See examples →

Planning the load

Container loading calculatorHow many pallets of wallboard fit in a 20GP, 40GP or 40HQVolumetric weight calculatorChargeable weight for samples sent by air

Sources

  1. USG: Sheetrock UltraLight Panels submittal (WB2501)Sizes, thickness, weight and ceiling limits of UltraLight. Checked 28 October 2026.
  2. USG: Sheetrock gypsum panels 1/4 and 3/8 in submittal (WB1473)Sizes and weights of the 1/4 and 3/8 in panels. Checked 28 October 2026.
  3. CertainTeed: Easi-Lite data sheetSizes and weights of Easi-Lite. Checked 28 October 2026.
  4. Georgia-Pacific: ToughRock Lite-Weight gypsum boardSize tolerance and weight of ToughRock Lite-Weight. Checked 28 October 2026.
  5. National Gypsum: Gold Bond High Strength LITE submittal (hosted by Lowe’s)Sizes and weight of High Strength LITE. Checked 28 October 2026.
  6. PABCO Gypsum: Regular submittalSizes and weights of PABCO Regular. Submittal of November 2024, checked 28 October 2026.
  7. Siniat: Standard Board technical data sheetWeights and EN 520 type of Standard Board. Sheet of 2019, checked 28 October 2026.
  8. Siniat: plasterboard portfolio leaflet (2024)Board sizes by thickness and edge. Leaflet of 2024, checked 28 October 2026.
  9. British Gypsum: Gyproc WallBoard data sheet (April 2015, Camden planning file)Sizes and weights of Gyproc WallBoard. Sheet of April 2015, checked 28 October 2026.
  10. Knauf UK: Wallboard environmental product declaration (2022, hosted by Travis Perkins)Sizes and weights of Knauf Wallboard. Declaration of 2022, checked 28 October 2026.
  11. Gypsum Association: GA-223-2017, gypsum panel products types, uses, sizes and standards (hosted by InspectApedia)Widths, lengths and uses by thickness, and the metric designations. Edition of 2017, checked 28 October 2026.
  12. Georgia-Pacific: ToughRock technical guideThe 54 in board for 9 ft walls. Checked 28 October 2026.
  13. IRC 2021 chapter 7, wall covering (2021 Seattle Residential Code)Table R702.3.5, note d and R702.3.5.1. 2021 edition, checked 28 October 2026.
  14. Gypsum Association: GA-235-10, typical properties of gypsum boards (hosted by InspectApedia)Design dead loads. Edition of 2010, checked 28 October 2026.
  15. Gypsum Association: GA-801-2023, handling and storage of gypsum panel products (hosted by PABCO)Panel weight, two-person handling and stack height. Edition of 2023, checked 28 October 2026.
  16. IRC 2021 chapter 3, building planning (2021 Seattle Residential Code)R302.6, R302.7 and R316.4. 2021 edition, checked 28 October 2026.
  17. National Gypsum: Gold Bond gypsum board submittal, older edition (hosted by Construction Instruction)Ceiling insulation by spacing. Checked 28 October 2026.
  18. American Gypsum: ClassicRoc submittalCeiling insulation and spacing of ClassicRoc. Checked 28 October 2026.
  19. Knauf Germany: Bauplatte GKB data sheet (September 2025, hosted by Heinze)EN 520 tolerances of the GKB board. Sheet of September 2025, checked 28 October 2026.
  20. Siniat: Drywall Manual book 2, partitions (v2.2.0, July 2025)Stud centres, screw centres and screw length. Book of July 2025, checked 28 October 2026.
  21. Siniat: Drywall Manual book 5, floors and ceilings (v2.0.0, June 2025)Joist centres for ceiling boards. Book of June 2025, checked 28 October 2026.